Sign In
Labcorp Oklahoma, Inc.
Test Directory


Index:

Soluble Transferrin Receptor

Order Name SOLUBL TRN
Test Number: 3604710
Revision Date 08/29/2023
Test Name Methodology LOINC Code
Soluble Transferrin Receptor
Immunochemiluminometric (ICMA)  
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 1 mL (0.2 mL) Serum Clot Activator (Red Top, No-Gel) Refrigerated
Alternate 1 1 mL (0.2 mL) Plasma EDTA (Lavender Top) Refrigerated
Alternate 2 1 mL (0.2 mL) Plasma Sodium Heparin (Green Top / No-Gel) Refrigerated
Instructions Notes: 0.2 mL (Note: This volume Does NOT allow for repeat testing.)
Specimen Type: Red-top tube or green-top (heparin) tube or lavender-top (EDTA) tube
Specimen Storage: Refrigerated
Specimen Collection: Separate serum or plasma from cells and transfer to a plastic transport tube.
Specimen Stability: Ambient: 14 days, Refrigerated : 14 days, Frozen: 14 days
GENERAL INFORMATION
Expected TAT 2-3 Days  
Clinical Use Elevated sTfR values are found in anemia of chronic disease (ACD), iron deficiency anemia (IDA), polycythemia, hemolytic anemia, thalassemia, hereditary spherocytosis, sickle cell and megaloblastic anemia, myelodysplastic syndrome and vitamin B12 deficiency. Elevated sTfR concentrations occur during pregnancy when there is a deficiency of functional iron. 
Performing Labcorp Test Code 143305 
Notes Labcorp Test Code: 143305
CPT Code(s) 84238
Lab Section Reference Lab